What are the main components of Ice Making Condensing Units?
Jan 09,2026How to replace a broken car air conditioner evaporator?
Jan 02,2026How to determine if the condensing unit capacity selection is appropriate?
Dec 26,2025Why does the evaporator always scale up?
Dec 19,2025What are the commonly used refrigerants in a Refrigeration System and their applicable ranges?
Dec 12,2025Noise and Vibration Problems of High-Power Compressor Condensing Units
1. Structural Noise Transmission
The operation of a high-power condensing unit generates strong mechanical vibrations between the compressor mounting feet and the base plate, which radiates high-frequency noise (approximately 800Hz) through the base plate, becoming the main source of noise.
When the air noise from the fan and compressor itself is reduced, structural noise often becomes dominant, requiring specialized vibration isolation design for suppression.
2. Resonant Frequency Conflict
If the natural frequencies of the compressor feet, vibration isolation elastomer, and base plate are similar, it will lead to resonance amplification, causing noise peaks exceeding 10dB in specific frequency bands (e.g., 800Hz).
By increasing the stiffness of the compressor feet, reducing their mass, or adjusting the damping of the vibration isolation elastomer, the resonant frequency can be effectively shifted out of the critical noise band, reducing structural noise.
3. High-Frequency Vibration Control Measures
Multi-degree-of-freedom (MDOF) vibration models are used for simulation to accurately identify the modal characteristics of each component, guiding the optimized design of vibration isolators, compressor feet, and base plates.
In actual products, improvements to the compressor foot structure (increasing stiffness and reducing end mass) have achieved a noise reduction of approximately 10 dB, shifting the overall noise level from compressor-dominated to fan-dominated.
4. Noise Control Advantages of Taizhou Best Refrigeration
In the development of the LKPG series high-power condensing units, the company has introduced advanced vibration isolation technology and structural optimization solutions to ensure that international standards for low noise and low vibration are met across a power range of 1/4–100 HP.
←
How to quickly handle refrigerant leaks or icing in a Refrigeration System?
→
What are the common cooling methods for compressor condensing units?
224 Yongping Road, Science and Technology Enterpreneurship Park, Gaogang District, Taizhou City, Jiangsu Province
+86-18082061600
[email protected]
Copyright © 2024 Taizhou Best Refrigeration Equipment Manufacturing Co., Ltd All Rights Reserved. Refrigeration Equipment Manufacturer Custom Refrigeration Equipment Factory